Elko eLAN-RF-003 Manual de instrucciones Pagina 32

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 52
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 31
32
32
32
60mm
21mm
<0.5s
<0.5s >0.5s >0.5s
<0.5s
<0.5s >0.5s
<0.5s
a b c
<0.5s
<0.5s >0.5s >0.5s
<0.5s
<0.5s >0.5s
<0.5s
a b c
t=3s
t=3s
t=3s
<0.5s
<0.5s >0.5s >0.5s
<0.5s
<0.5s >0.5s
<0.5s
a b c
t=3s
t=3s
<0.5s <0.5s
<0.5s >0.5s
<0.5s
<0.5s >0.5s
<0.5s
<0.5s
<3s
<3s >3s <3s >3s
<3s
<3s
a b c
3s
3s
RFDA-11B RFDA-71B
RFDA-11B RFDA-71B
N
L
L
VN
RFDA-11B
RFDA-71B
R L C
N
L
L
V
N
RFDA-11B
RFDA-71B
R L C
N
L
L
V
N
RFDA-11B
RFDA-71B
R L C
Function 1 - press 1x Function 2 - press 2x
Function 3 - press 3x Function 4 - press 4x
Sunrise - press 5x Sunset - press 6x ON/OFF - press 7x
a) Press the button for less than 0.5 seconds to switch on the light;
press again to switch it o .
b) Press and hold the button for more than 0.5 seconds to adjust
brightness continuously. After releasing the button, the brightness
level is saved into memory and pressing the button shortly later
will switch on/o the light to this intensity.
c) Brightness may be adjusted at any time by pressing and holding
the button. The receiver remembers the adjusted value even after
disconnecting from power supply.
If the light is o , press the button to
switch it on. If the light is on, press the
button to switch it o .
After pressing the button, the light will
start to switch on during the selected
time period, ranging from 2 seconds to
30 minutes.
After pressing the button, the light will
start to switch o during the selected
time period, ranging from 2 seconds to
30 minutes.
a) Press the button for less than 0.5 seconds to continuously switch on
the light for 3 seconds (at 100% brightness). By pressing the button
shortly again, the light will continuously switch o for 3 seconds.
b) Press and hold the button for more than 0.5 seconds to adjust
brightness continuously. After releasing the button, the brightness
level is saved in the memory and pressing the button shortly later
will switch on/o the light to this intensity.
c) Brightness may be adjusted at any time by pressing and holding
the button. The receiver remembers the adjusted value even after
disconnecting from power supply.
a) Press the button for less than 3 seconds to switch on the light; press
again to switch it o .
b) To avoid undesirable brightness adjustment, the continuous
brightness regulation is only activated pressing and holding the
button for more than 3 seconds. After releasing the button, the
brightness level is saved in the memory and pressing the button
shortly later will switch on/o the light to this intensity.
c) Brightness may be adjusted by pressing and holding the button
for more than 3 seconds at any time. The receiver remembers the
adjusted value even after disconnecting from power supply.
a) Press the button for less than 0.5 second to switch on the light,.
By pressing the button shortly again, the light will continuously
switch o for 3 seconds (at 100% brightness).
b) Press and hold the button for more than 0.5 second to adjust
brightness continuously. After releasing the button, the brightness
level is saved into memory and pressing the button shortly later
will switch on/o the light to this intensity.
c) Brightness may be adjusted at any time by pressing and holding
the button. The receiver remembers the adjusted value even after
disconnecting from power supply.
t=2s..30min t=2s..30min
serves for light dimming and creating light scenes (4 preset light scenes)
allows dimming bulbs and halogen lights with electronic or wound R, L, C 250VA transformer
RFDA-11B: single-function - button dimmer
RFDA-71B: multifunction - 6 light functions, ON/OFF function, possibility to set continuous switching on/o of
light (between 2 seconds and 30 minutes)
easy control: switch on/o the light by pressing the button shortly; adjust brightness by pressing and holding
each actuator can be controlled by up to 32 channels (1 channel is represented by 1 button on the wireless wall
switch button, keychain or the RF Touch-W / B unit)
electronic overcurrent protection - the output is switched o in case of overloading or short-circuit
for programming and manual control, press the Prog button
installation box design (such as KU-68)
Supply voltage:
Apparent input:
Dissipated power:
Supply voltage tolerance:
Connection:
Output
Resistance load:
Capacity load:
Inductive load:
Control:
RF, by command from transmitter:
Manual control:
Range in free space:
Other data:
Operating temperature:
Operating position:
Mounting:
Protection:
Overvoltage category:
Contamination degree:
Terminals (CY wire, cross-section):
Length of terminals:
Dimensions:
Weight:
Related standards:
Technical parameters
230 V AC / 50 Hz
8.3 VA / cos φ = 0.1
0.83 W
+10/ -15 %
3 conductors, including neutral
250 VA*
250 VA*
250 VA*
868 MHz
PROG (ON/OFF)
up to 160 m
-15 to + 50 °C
any*
free at lead-in wires
IP 30
III.
2
3x0.75 mm
2
90 mm
49 x 49 x 21 mm
40 g
EN 60669, EN 300 220, EN 301 489
Directives RTTE,Gov. Reg. No..426/2000Sb(Directives 1999/EC))
!
!
!
!
!
!
!
!
Wiring with diff erent types of loadDevice description
CONTROLS
EAN code
RFDA-11B: 8595188136846 / RFDA-71B: 8595188143080
Device status indicator
Output to appliance
Program button (ON/OFF
manual control)
Neutral conductor
Phase conductor
R-Resistance L-Induction C-Capacity
RF receiver: Dimming actuator RFDA-11B, RFSA-71B
* For more information, see p. 48